Furthermore we offer color glass filters, thin film filters, beamsplitter plates and cubes. Special capabilities in micro optics (down to 0.2 mm) and large components up to 3200 x 400 mm complete the product line. One of our key differentiators is highly accurate surfaces on large substrates (e.g. lambda/4 on 300 mm diameter).
Depending on material and geometry the following specifications can be achieved:
• Dimensions from 2 mm up to 1000 mm or more
• Flatness up to lambda/40 P-V
• Parallelism or angular accuracy of 1 arc sec
• Surface quality up to 5 / N x 0.001 according to ISO 10110-7 or S-D 10-5 according to MIL-PRF-1383B
Additionally achromats or other multi-element lenses made of different materials are manufactured to print or designed to meet your requirements.
Depending on the type of component and material requested the following specifications can be achieved:
• Dimensions up to 150mm or more on request
• Surface figure up to lambda/10 P-V
• Surface quality up to 5 / N x 0.001 according to ISO 10110-7 or S-D 10-5 according to MIL-PRF-1383B
• AR–coatings like single layer (R<1.5%), multi-layer (R<0.25%), broadband (Ravg<0.4%) or laser grade (R<0.15%) with selectable wavelength / wavelength range
• Metallic reflective coatings as Aluminum, Silver or Gold
• High reflective dielectric coatings (R>99.8%)
• ND-Filter coatings
• Dichroic filter coatings (color filter, heat reflection, cold-light, etc.)
• Beam splitter coatings (single wavelength or broadband for VIS, UV, IR, polarizing or non-polarizing)
• Other coatings on request
Consistent quality can only be ensured by clear procedures and appropriate measuring devices. Therefore
we use the most up-to-date equipment to guarantee the quality of our products. In our QC rooms we use:
Interferometers
- Zygo-GPI-XP
- LT Ultra-12"
- Fisba
µPhase® FS50
- Fisba
µPhase® FST H100
Spectrophotometer
- PerkinElmer
Lambda 950
Autocollimator
- Zeiss
Bounding and Centering
- Trioptics OptiCentric
Goniometer
- Trioptics PrismMaster
and we use Euromex microscopes for surface inspection
Even the flatness of larger surfaces
up to 300 mm diameter (12”) can be measured as a whole. On request we supply appropriate documentation
like interferograms, spectral curves, etc.